BYVNM - CARBON CONDUCTING PAINT, 23014

  • MSDS: BYVNM
  • Manufacturer: POLYSCIENCES INC
  • Product Name: CARBON CONDUCTING PAINT, 23014
  • National Stock Number: 8010-00N063161
Product Identification

Product ID:CARBON CONDUCTING PAINT, 23014
MSDS Date:06/05/1995
FSC:8010
NIIN:00N063161
MSDS Number: BYVNM

Responsible Party
POLYSCIENCES INC
400 VALLEY RD
WARRINGTON, PA 18976
US

Emergency Phone: 215-343-6484

Info Phone: 215-343-6484

Cage: 9C365

Contractor
POLYSCIENCES INC
WARRINGTON, PA 18976 US

Telephone: 215-313-6484

Cage: 9C365

Ingredients

ISOPROPYL ALCOHOL; (ISOPROPANOL) (SARA 313)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 66%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM/500 STEL


GRAPHITE

CAS: 7782-42-5

RTECS: MD9659600

Fraction By Weight: 15%

OSHA PEL 15 MPPCF; Z-3

ACGIH TLV: 2 MG/M3 RDUST


N-BUTYL ALCOHOL; (N-BUTYL ETHER) (SARA 313) (CERCLA)

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: 5%

OSHA PEL 100 PPM

ACGIH TLV: S, C 50 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


HEXYLENE GLYCOL

CAS: 107-41-5

RTECS: SA0810000

Fraction By Weight: 5%

OSHA PEL C 25 PPM

ACGIH TLV: C 25 PPM


2-PROPANOL, 1-METHOXY-; (PROPYLENE GLYCOL MONOMETHYL ETHER)

CAS: 107-98-2

RTECS: UB7700000

Fraction By Weight: 5%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/150 STEL

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:POSSIBLE IRRITANT. ACUTE &
CHRONIC:NONE LISTED BY MANUFACTURER. CHEMICAL, PHYSICAL AND
TOXICOLOGICAL PROPERTIES ARE NOT ESTABLISHED FOR THIS MATERIAL.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NOT KNOWN.

First Aid

First Aid:SKIN:WASH AFFECTED AREA W/COPIOUS AMTS OF WATER. EYE:FLUSH
W/WATER FOR @ LEAST 15 MINUTES. INHAL:REMOVE TO FRESH AIR. GIVE
OXYGEN OR ARTIFICIAL RESPIRATION, AS NEEDED. INGEST:CALL PHYSICIAN.
SEEK MEDI CAL TREATMENT IF DISCOMFORT PERSISTS.

Fire Fighting

Flash Point:52.0F,11.1C
Extinguishing Media:WATER, CARBON DIOXIDE, DRY CHEMICAL POWDER, FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:USE WATER SPRAY TO DISPERSE VAPOR.

Accidental Release

Spill Release Procedures:WEAR NIOSH/MSHA APPRVD SCBA, RUBB BOOTS &
GLOVES. ABSORB ON SAND, VERMICULITE, SAWDUST & PUT IN CONTAINER FOR
FUTURE DISPOSAL. WASH & VENTILATE SPILL SITE AFTER PICKUP IS
COMPLETE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE MATERIAL AT 25C. KEEP STORAGE
CONTAINER TIGHTLY CLOSED.
Other Precautions:AVOID CONTACT WITH SKIN AND EYES. DO NOT INHALE.
HANDLE WITH CARE REQUIRED BY GOOD LABORATORY TECHNIQUE.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:MECHANICAL VENTILATION.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMERGENCY EYE WASH & DELUGE
SHOWER .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Vapor Pres:31 @ 20C
Spec Gravity:0.89
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:NOT KNOWN
Appearance and Odor:THIXOTROPIC BLACK FLUID.
Percent Volatiles by Volume:80

Stability

Stability Indicator/Materials to Avoid:YES
NOT KNOWN.
Stability Condition to Avoid:HIGH TEMPERATURE.
Hazardous Decomposition Products:NOT KNOWN.

Disposal

Waste Disposal Methods:DISSOLVE OR MIX MATL W/COMBUSTIBLE. DISPOSE OF
INSOLVENT & BURN IN AN EPA LICENSED CHEMICAL INCINERATOR EQUIPPED
WITH AN AFTERBURNER & SCRUBBER. DISPOSE IN COMPLIANCE WITH ALL
LOCAL, STATE, AND FEDERA L REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.